Rect-to-round transition are used between rectangular and circular
ducts. The rectangular connection has joining profiles type RJFP and the
circular connection has Safe seal. The rectangular connection is available with offsets as in the coded sketches.Measures e and h only need to be given for alternative 6. Negative values for e, for example, mean that e is outside side a.
Read more...
Bend with rounded outer corner, stiffened with trapezoid corrugations.The
bend is delivered with 90° or 45° angles and joining profiles type RJFP
at both ends. Other leg lengths and angles can also be ordered.Standard design l1 = l2 = 125 mm.
Used for deflections of the duct system, for example where ducts cross.Has a joining profile type RJFP at both ends, and is stiffened by trapezoid corrugations.A
special relationship is needed between the a-dimension, fall f and
length l for the LBSR to retain its cross-sectional area and not
restrict the air flow. For this reason, standard lengths and standard
drops have been prepared.
Bend with sharp outer corner, stiffened with trapezoid corrugation. The
bend is delivered with 90° or 45° angles and joining profile RJFP at
both ends. Other leg lengths and angles can also be ordered.Standard design l1 = l2 = 125 mm.
The
taper is used as transition between different duct dimensions. The
larger dimensions are available with offsets as in the coded sketches.Dimension changes have a joining profile type RJFP at both ends, and are stiffened by trapezoid corrugations.Measures e and h only need to be given for alternative 6. Negative values for e, for example, mean that e is outside side a.
Straight duct, stiffened with transverse trapezoid corrugations, which
reduces the risk of noise generation. Larger dimensions have stiffening
profiles and/or internal rods. Installation height of these profiles is
23 mm.
A T-piece which is provided with joining profiles type RJFP and is stiffened with trapezoid corrugations.Standard design l1 = l2 = l3 = 125 mm.Other leg lengths can also be supplied.
The collar is used for connection to circular duct. The rectangular end is provided with joining profiles type RJFP. The rounded end has an edge, for fixing with blind rivets or self-tapping screws.Other lengths can also be supplied.
Joining profile LS 1Joining
profile designed to be fixed to the duct by embossing with a special
pincers. It is sealed to the duct by special factory-applied seam putty.
Profile height is app. 20 mm. Normally supplied in 5 m lengths.Specific weight: 0,40 kg/m
Rectangular Duct Rod CrossThe metal cross is used for large ducts.
The plastic cross is used for small ducts.
Rectangular Joint Bolt Clamp.The clamp is easy to use where there is sufficient space to fasten the clamp.
RJFPC3 Rectangular Joint Flange Profil comes in three sizes, different sheet steel thicknesses, with and without sealant.
Rectangular Joint Seal Moulding.The 9 mm seal moulding is to be used with RJFP 20 profileThe
12 mm seal molding is to be used with RJFP 30 and 40 profiles or as
sealing in between two flanges FL, see catalogue page for FL for more