Pressed and seam welded bend with separate branch for cleaning. The stud
is fitted with a Safe take-off and fits an inspection cap.
Pressed and seam welded bend with separate branch for cleaning. The stud is fitted with a Safe take-off and fits an inspection cap. The design gives a lower pressure drop than the equivalent design using a T-piece. The stud can also be used as the connection for an SR duct.
Pressed and seam welded bend with separate branch for cleaning. The stud
is fitted with a Safe take-off and fits an inspection cap.
Circular duct.Ducts are always produced locally and can therefore have different thicknesses and other specifications per country.The ducts can be produced both with and without click function (notches).
Please specify when ordering.
Take-off without radius. With female end – fits outside a Safe fitting. Hasn’t any Click function – hasn’t any notches.
Female coupling for joining fittings.Has normally not any Click function – hasn’t any notches.Ø 80–315 can upon order be delivered with click function – i.e. with notches.
Pressed saddle with aerodynamic flow radius facing the branch.Some PSUs are pressed with one and the same tool, and fit several dimensions of main pipe.
Pressed, concentric reducer with female coupling to meet demands for short installation length...
Read more...
Pressed, concentric reducer to meet demands for short installation
length with low pressure drop and low internal noise generation.
Areas of use: To avoid the necessity of an exact length cutting of a duct when it is difficult to take a proper measure.
Read more
...
Areas of use: To eliminate the accurate length cutting of ducts which the ordinary NPU...
Read more...
T-piece built with PSU saddle or a fully pressed top section. Pressure drop, see graphs on page TCPUPSU Technicaldata.
X-piece, hand made with saddle PSU.Ød4 can also have a different dimension than Ød3.
The EBSRN is used for the covering the insulation on SRIN/SRIPN when connecting with uninsulated ducts or fittings.
ESRIPN is an endcap for perforated ducts. It provides an airtight sealing towards the rest of the ductsystem.
The transition piece with female coupling, is double-jacketed and
insulated at the large end and supplied with Lindab Safe rubber seal at
the small end. It’s used when going from insulated to non insulated
ductwork.
The transition piece is double-jacketed and insulated at the large end
and supplied with Lindab Safe rubber seal in the inner dimension. It’s
used when going from insulated to non insulated ductwork.
The end cap is double-jacketed, insulated with mineral wool and with Lindab Safe rubber seal on the inner dimension. It fits inside a duct.
The bend is double-jacketed and insulated with mineral wool, and is supplied with Lindab Safe rubber seal on the inner dimension.With stop bead at both inner and outer part to ensure correct installation.
The
bend is double-jacketed and insulated with mineral wool, and is
supplied with Lindab Safe rubber seal on the inner dimension.With stop bead at both inner and outer part to ensure correct installation.
The
bend is double-jacketed and insulated with mineral wool, and is
supplied with Lindab Safe rubber seal on the inner dimension.With stop bead at both inner and outer part to ensure correct installation.
The
bend is double-jacketed and insulated with mineral wool, and is
supplied with Lindab Safe rubber seal on the inner dimension.With stop bead at both inner and outer part to ensure correct installation.
The
bend is double-jacketed and insulated with mineral wool, and is
supplied with Lindab Safe rubber seal on the inner dimension.With stop bead at both inner and outer part to ensure correct installation.
Coupling for fittings. The coupling is double-jacketed and insulated with mineral wool.
The coupling is double-jacketed and supplied with Lindab Safe rubber seal on the inner dimension and used when connecting insulated ducts. With distance ensuring that the parts are centered.
Download PDF
The reducer is double-jacketed and insulated with mineral wool, and is supplied with Lindab Safe rubber seal on the inner dimension (Ød2) and female connection at the inner dimensions (Ød).
The reducer is double-jacketed and insulated with mineral wool, and is
supplied with Lindab Safe rubber seal on the inner dimensions.
The transition piece is supplied with Lindab Safe rubber seal.The transition piece is used when connecting the duct system to the bulkhead penetrations.
The duct is double-jacketed and insulated with mineral wool and has an attenuating effect. Internal duct is perforated.Perforation: 3 mm holes. Triangulation: 5 mm.Open: 32,6%.
The T-piece is double-jacketed and insulated with mineral wool, and is supplied with Lindab Safe rubber seal on the inner dimension.With stop bead at the main connedtions, to ensure correct installation.
The
transition piece is double-jacketed and insulated with mineral wool,
and is supplied with Lindab Safe rubber seal on the inner dimension.Used when connecting insulated duct systems to Lindab standard insulated Marine system.
Coupler for fittings. The MFIN is double-jacketed and insulated with mineral wool.
The reducer is double-jacketed and insulated with mineral wool, and is
supplied with LindabSafe rubber seal in the inner dimension.
Rect-to-round transition are used between rectangular and circular
ducts. The rectangular connection has joining profiles type RJFP and the
circular connection has Safe seal. The rectangular connection is available with offsets as in the coded sketches.Measures e and h only need to be given for alternative 6. Negative values for e, for example, mean that e is outside side a.
Read more...
Bend with rounded outer corner, stiffened with trapezoid corrugations.The
bend is delivered with 90° or 45° angles and joining profiles type RJFP
at both ends. Other leg lengths and angles can also be ordered.Standard design l1 = l2 = 125 mm.
Used for deflections of the duct system, for example where ducts cross.Has a joining profile type RJFP at both ends, and is stiffened by trapezoid corrugations.A
special relationship is needed between the a-dimension, fall f and
length l for the LBSR to retain its cross-sectional area and not
restrict the air flow. For this reason, standard lengths and standard
drops have been prepared.
Bend with sharp outer corner, stiffened with trapezoid corrugation. The
bend is delivered with 90° or 45° angles and joining profile RJFP at
both ends. Other leg lengths and angles can also be ordered.Standard design l1 = l2 = 125 mm.
The
taper is used as transition between different duct dimensions. The
larger dimensions are available with offsets as in the coded sketches.Dimension changes have a joining profile type RJFP at both ends, and are stiffened by trapezoid corrugations.Measures e and h only need to be given for alternative 6. Negative values for e, for example, mean that e is outside side a.
Straight duct, stiffened with transverse trapezoid corrugations, which
reduces the risk of noise generation. Larger dimensions have stiffening
profiles and/or internal rods. Installation height of these profiles is
23 mm.
A T-piece which is provided with joining profiles type RJFP and is stiffened with trapezoid corrugations.Standard design l1 = l2 = l3 = 125 mm.Other leg lengths can also be supplied.
The collar is used for connection to circular duct. The rectangular end is provided with joining profiles type RJFP. The rounded end has an edge, for fixing with blind rivets or self-tapping screws.Other lengths can also be supplied.
Joining profile LS 1Joining
profile designed to be fixed to the duct by embossing with a special
pincers. It is sealed to the duct by special factory-applied seam putty.
Profile height is app. 20 mm. Normally supplied in 5 m lengths.Specific weight: 0,40 kg/m
Rectangular Duct Rod CrossThe metal cross is used for large ducts.
The plastic cross is used for small ducts.
Rectangular Joint Bolt Clamp.The clamp is easy to use where there is sufficient space to fasten the clamp.
RJFPC3 Rectangular Joint Flange Profil comes in three sizes, different sheet steel thicknesses, with and without sealant.
Rectangular Joint Seal Moulding.The 9 mm seal moulding is to be used with RJFP 20 profileThe
12 mm seal molding is to be used with RJFP 30 and 40 profiles or as
sealing in between two flanges FL, see catalogue page for FL for more
information.
Manual
regulation damper. The damper is double-jacketed and insulated with
mineral wool and is supplied with Safe rubber seal on the inner
dimension.With stop bead to ensure correct installation.
Manual closing damper, without sealing at the blade.The damper is double-jacketed and insulated wiht mineral wool and is supplied wiht saferubber seal on the inner dimension.With stop bead to ensure correct installation.
INDTMU
are tight-closing shut-off dampers. The damper is double-jacketed,
insulated with mineral wool and supplied with Safe rubber seal on the
inner dimension. With stop bead to ensure correct installation.Equipped with a handle and a locking mechanism for stepless adjustment of 0–90°.Ø 80–315 fullfills pressure class C in closed position.
Insulated
tight close damper. The damper is double-jacketed and insulated with
mineral wool and is supplied with Safe rubber seal on the inner
dimension.With stop bead to ensure correct installation.
Has
a turning, cut-off blade. The blade is stepless adjustable 0–90°. The
damper admits an insulation thickness of approx. 50 mm.The blade
is designed to generate a minimum of noise. The noise is approx. the
same as for a perforated blade. But the blade is less sensitive to
clogging since it lacks perforations.Setting the blade angle at the rim of the cup (a)a = 0° = open blade
a = 90° = closed blade
Has
a turning, circular blade. The blade is stepless adjustable 0–90°. The
damper is used when you have lower demands for shut-off capacity. The
damper admits an insulation thickness of approx. 50 mm.The damper can on occations be used for regulation.Setting the blade angle at the rim of the cup (a)a = 0° = open blade
a = 90° = closed blade
One-way dampers are used to prevent natural back-flows. It can be mounted both vertically and horizontally (note the arrow marking) and are designet to be installed near the outlet.At horizontal installation please make sure that the sticker (UP) is at the top.
Has a turning circular blade with an EPDM-rubber seal which tightens against the inside of the damper when closed. The blade can be adjusted in a 090 angle...
Read more...
Constant flow damper with electric motor for switching between two flowsDA2EU is a constant flow damper, which facilitates balancing of ventilation systems and gives correct flow from the start...
Read more...
Constant flow damper with manual setting of one flow DAU is a constant flow damper, which facilitates balancing of ventilation systems and gives correct flow from the start...
Read more...
The
non-return damper is double-jacketed and insulated with mineral wool,
and is supplied with Safe rubber seal in the inner dimension. With stop bead to ensure correct installation.
The non-return valve is double-jacketed and insulated with mineral wool,
and is supplied with Safe rubber seal in the inner dimension.
Constant flow damper with electric motor for continuous setting of one flow...
Read more...
The damper DIRU with flow meter offers measurement of the air flow...
Read more...
The meter is suitable both for setting up and for continous flow measurement...
Read more...
The silent duct type SDO consists of an outer pipe, a perforated inner pipe, a lining.
Read more...
SLFA 25 is a flexible silencer that can be adapted to any installation situation.
Read more...
MINKA is a rectangular duct attenuator in galvanized steel* with baffles (splitters) filled with felt coated mineral wool attenuation material.
Read more...
Application
The
Controller is suitable for measuring and controlling air flow and
measuring temperature. Communication is established via analog signals
or digital signal using Modbus. There is also an option to wireless
connect to the Controller via Bluetooth.
Design
The Controller consists of a sensor body attached to a damper body with Lindab Safe gaskets.
Two
flow sensors are mounted on the sensor body and connected to a display
unit. The display unit is mounted on top of a shelf on the damper body.
Application
The
Controller is suitable for measuring and controlling air flow and
measuring temperature. Communication is established via analog signals
or digital signal using Modbus.
The Controller can also be commissioned via Bluetooth. The
UltraLink App is the perfect tool to monitor and adjust the airflow
directly via a mobile device, which speeds up installation and
commissioning.
Design
The Controller consists of a sensor body attached to a damper body with Lindab Safe gaskets.
Two
flow sensors are mounted on the sensor body and connected to a display
unit. The display unit is mounted on top of a shelf on the damper body.
The product has a pre-mounted cable which makes it easy to connect.
Application
The
Monitor is suitable for measuring air flow and temperature.
Communication is established via analog or digital signal using Modbus.
There is also an option to wireless connect to the Monitor via Bluetooth.
Design
The Monitor consists of a sensor body with Lindab Safe gaskets.
Two
flow sensors are mounted on the sensor body and connected to a display
unit. The display unit is mounted on top of a shelf on the sensor body.
circular diffuser with a closed front plate and a regulating handle suitable for...
Read more...
circular diffuser with a closed insulated front plate and a regulating handle suitable for...
Read more...
flush mounted circular diffuser with a circular unperforated face plate for installation...
Read more...
flush-mounted square diffuser with a circular unperforated face plate for installation ...
Read more...
flush-mounted square diffuser with a square unperforated face plate for installation...
Read more...
rotation diffuser particularly suitable for rooms with a high ceiling...
Read more...
d...
circular perforated diffuser that can be used for both supply air and extract air...
Read more...
circular diffuser with perforated face plate and integrated swirl insert...
Read more...
Valve for supply air.Designed for ceiling mounting.Bayonet holders connect to socket VRGU, VRGL or VRGM.
Valve for exhaust air.
Designed for wall or ceiling mounting.
Bayonet holders connect to socket VRGU, VRGL, or VRGM.
Exhaust valve. In special cases the URH valve can be used as an supply air valve for installation in a wall (relatively long throw).
RGS is a rectangular ventilation grille with vertical adjustable bars...
Read more...
The opposed blade damper DGAN can be fitted to the AD, AL, AR and AC aluminium grilles.